ABOUT PRODUCTS
This system is used for monitoring the data of any universal input. The data logger will log the data with user settable interval and the data will be download by connecting the pen drive or through the PC software
| Technical Specification | Description |
| Input | RTD : PT100, 3 wire. Thermocouple : J,K,R,S,T,N. DC mA : 0-20mA , 4-20mA DC mV : 0-250mV, 0-500mV DC V : 0-1V, 0-2V, 0-5V, 0-10V |
| Display | 10.4" Touch Screen HMI display |
| Data Storage | 1 Lakh Samples |
| Log In Interval | User Selectable - 1/5/10/15/30Sec, 1/5/10/15/30/60min |
| Resolution | RTD (PT100) : XXX.X Thermocouple: XXX.X DC mV/V/mA : X.XXX / XX.XX / XXX.X / XXXX |
| USB Port | USB 2.0 Type A For easy data retrieval in .CSV format. |
| Alarm Type | User settable Alarm point for individual channels. Alarm indication available on display screen. Optional Relay output available. Alarm Types: Low, High, High-Low. |
| Relay | 2 Nos NO/POLE alarm relay (Grouping) Relay 1: Common for all channels or user select the channels. Relay 2: Common for all channels or user select the channels. |
| Power Supply | 12VDC (230VAC to 12VDC adapter can be provided) |
| Operating Temperature | 10 to 50°C and 10 to 90% RH. |